Digital View 559000105?3 Spezifikationen Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
Specifications subject to change without notice
© Digital View Ltd – Doc Ver 1.2: 3 Dec, 2010 (AVP-1600_manual.doc) Page
22 of 35
TROUBLESHOOTING
General
A general guide to troubleshooting a flat panel display system it is worth considering the system as
separate elements, such as:
¾ Controller (jumpers)
¾ Panel
¾ Backlight (inverter, cabling, backlight tubes)
¾ Cabling
¾ Video Source
Through step by step cross checking with instruction manuals and a process of elimination to isolate
the problem it is usually possible to clearly identify the problem area.
No image:
¾ If the panel backlight is not working it may still be possible to just see some image on the display.
¾ A lack of image is most likely to be caused by incorrect connection, lack of power, failure to
provide a signal.
Image appearance:
¾ A faulty panel can have blank lines, failed sections, flickering or flashing display
¾ Incorrect jumper settings on the controller may cause everything from total failure to incorrect
image. CAUTION: Do not set the panel power input incorrectly.
¾ Sparkling on the display: faulty panel signal cable.
Backlight:
Items to check include: Power input, Controls, Inverter and Tubes generally in this order.
If half the screen is dimmer than the other half:
¾ Check cabling for the inverter.
¾ For a specific backlight tube check the AC pins orientation (CAUTION: Never reverse any DC
power pins).
Also:
¾ If adjusting brightness control has no effect the chances are that the VR rating or method of
adjusting brightness is not compatible or correctly connected to the inverter.
¾ If system does not power down when there is a loss of signal
Continued failure:
If unit after unit keeps failing consider and investigate whether you are short circuiting the equipment
or doing something else seriously wrong.
Generally after common sense issues have been resolved we recommend step by step substitution of
known working parts to isolate the problem.